Boost Services Heating and CoolingBlog

Notes from the field

Plain answers on air conditioning, heating, heat pumps, mini splits, ducts and thermostats.

Page 7 of 10

Back to the blog

A blower motor and its wiring inside an HVAC unit
Heating

Heater Blowing Cold Air: The Usual Causes

The fan left on ON, a clogged filter tripping the limit switch, a pilot or igniter that is not lighting, or attic ducts losing the heat on the way.

Rooftop package unit with disconnect
AC troubleshooting

AC Tripping the Breaker? The Timing Tells You Why

Instantly means a short to ground. After a second of humming, the capacitor. After 10 to 30 minutes on a hot afternoon, a dirty coil. Reset once only.

A row of palm trees against a blue sky
AC troubleshooting

AC Runs Constantly and the House Stays Hot? Read the Split

A 15 to 20 degree drop between the return and a supply register means the refrigerant side is fine. Under 10 points at airflow or charge.

Boost technician fabricating ductwork on site
AC troubleshooting

AC Leaking Water Inside: Drain Line, Pan, or Frozen Coil

The coil makes the water and the drain carries it out. How to tell which part failed, and the vinegar and wet-vac checks that clear a mild clog.

Copper windings inside an opened electric motor
AC troubleshooting

AC Buzzing, Rattling, or Hissing? What Each One Means

Buzzing is electrical, rattling is something loose, hissing can be refrigerant. Five of these sounds mean shut it off at the thermostat before you call.

An outdoor heating and cooling unit in the rain beside a garden
AC troubleshooting

AC Short Cycling? The Filter Is the Most Common Cause

A healthy cycle runs fifteen minutes or more. Why a dirty filter, a weak capacitor, or a system one size too big all end in a two-minute cycle.

Workers on a rooftop beside air conditioning units and ductwork
Commercial

Commercial HVAC Maintenance: The Small-Building Contract

Quarterly filters and belts, charge and amp readings twice a year, one coil cleaning. Ask for readings on the report, not checkmarks.

A hand adjusting a wall thermostat
Thermostats & controls

Smart Thermostats Save Money Only If the House Empties

Energy Star puts the average saving at roughly 8 percent, and the only lever is runtime. Where it pays here, and why a heat pump changes the setback math.

A new heat pump air handler Boost installed in a closet
Ducts & air quality

Duct Insulation R-Value: Why Attic Ducts Need R-8

Supply air leaves the coil near 55 degrees and the attic sits at 130. What R-4.2, R-6 and R-8 mean on the jacket, and why sealing comes first.

Sheet-metal duct transition on a commercial roof
Ducts & air quality

Duct Sealing or Replacement? Three Readings Decide It

Leakage, static pressure and the condition of the jacket. Gray flex that flakes and a single undersized return are replacement, not something you seal.

A grey Craftsman bungalow
Heat pumps

Ducted or Ductless Heat Pump? Start With the Attic

A 1920s bungalow with no ducts has three paths, including concealed-duct heads. Headroom, small rooms, and a MERV 13 filter slot decide which one fits.

Colorado Boulevard in Pasadena with the San Gabriel Mountains behind
Maintenance & seasonal

Fall HVAC Checklist: What to Do Before the First Cold Night

The AC still runs here into October, then the furnace gets asked for heat. Run it 15 minutes on a mild day, keep a spare filter, test the CO alarm.